Every community water system in the U.S. has to give its customers a water quality report once a year. Its official name is a Consumer Confidence Report, or CCR, and it’s usually due by July 1. Most people never read it, or never realize they got one.
It’s worth ten minutes. Here’s how to find yours and what each column in the table actually means.
Where to find your report
- Your utility’s website. Search for your water system’s name plus “water quality report” or “consumer confidence report.”
- EPA’s lookup tool. EPA keeps a Find Your Local CCR page that links to reports by state and system.
- Your water bill. Many utilities print the web address on the bill, or mail the report with it.
- If you rent, the report may go to your landlord. The utility’s website will still have it.
On a private well? There is no report for you. Private wells aren’t regulated the way public systems are, so testing is up to the owner. Penn State Extension recommends testing, and your county health department or a state-certified lab can tell you where to start.
Skip to the table
Most of a CCR is background: where the water comes from, how it’s treated, contact numbers. The part to read is the table of detected contaminants. Here’s what each column means, using EPA’s own definitions.
- Contaminant (units). What was measured, and the unit it’s reported in (see the unit guide below).
- MCLG, or Maximum Contaminant Level Goal. EPA’s definition: if the level in your water is below the MCLG, “there is no known or expected risk” to health. It’s a goal, not an enforceable limit.
- MCL, or Maximum Contaminant Level. The legal limit. Above it, the system is in violation.
- TT, or Treatment Technique. For some contaminants, EPA requires a treatment process instead of setting a number.
- MRDL and MRDLG. The same idea as MCL and MCLG, applied to disinfectants such as chlorine.
- Your Water. The highest level of that contaminant found during sampling. Some reports show an average instead, and the report should say which.
- Range. The lowest and highest levels detected across samples.
- Violation. Yes or No.
- Typical Source. Where that contaminant usually comes from.
Unit guide
- ppm (parts per million) is the same as mg/L.
- ppb (parts per billion) is the same as µg/L. 1 ppm = 1,000 ppb.
- ppt (parts per trillion) is the same as ng/L. 1 ppb = 1,000 ppt.
- pCi/L measures radioactivity. NTU measures cloudiness (turbidity).
Units trip people up more than anything else. A “4” in ppt is a thousand times smaller than a “4” in ppb, so check the unit before you compare numbers.
A worked example: nitrate
Here’s what a nitrate row might look like. These numbers are for illustration only. They aren’t from any real utility’s report.
| Contaminant | MCLG | MCL | Your Water | Range | Violation | Typical Source |
|---|---|---|---|---|---|---|
| Nitrate as N (ppm) | 10 | 10 | 4.1 | 1.2–4.1 | No | Fertilizer runoff; septic systems; natural deposits |
How to read it:
- “No violation” is accurate. 4.1 is below the legal limit of 10.
- It doesn’t mean “none.” Nitrate showed up in every sample. The lowest reading was 1.2 ppm.
- The range tells a story. Nitrate often rises and falls with the seasons, for example after spring fertilizer goes down. A wide range is worth noticing even when the top number is legal.
- Context. The 10 ppm limit traces back to a 1962 U.S. Public Health Service recommendation. The Environmental Working Group, an advocacy organization, argues for a far lower benchmark of 0.14 ppm. EPA’s limit remains 10. We wrote more about that in The Federal Nitrate Limit Dates to 1962.
Five things the table won’t tell you on its own
- “No violation” isn’t “not detected.” Compare “Your Water” with the MCLG, not only the MCL.
- Some results may be from an earlier year. Not every contaminant is tested every year. Look for the sample date next to the result.
- It measures the system, not your tap. Water can pick up material from the pipes between the treatment plant and your faucet, including the plumbing in your own building. Lead and copper are reported differently from everything else: as a “90th percentile” value compared against an “action level” (AL), rather than against an MCL.
- Unregulated contaminants get their own table. Many reports list substances EPA is monitoring but hasn’t set limits for. Since 2023, that nationwide monitoring has included PFAS, the “forever chemicals.”
- Standards change, in both directions. EPA set PFAS limits in 2024. In May 2026 it proposed rescinding some of them and giving utilities more time on others. As of November 2026, neither proposal had been reported as final.
The report itself is changing in 2027
EPA finalized revisions to the CCR rule in May 2024, and they take effect in 2027. Here’s what’s changing:
- Systems serving more than 10,000 people will send reports twice a year instead of once.
- Reports will open with a plain-language summary.
- They’ll include more information about lead.
- There will be more support for translation.
AWWA has a good summary of the details.
If you see something you’d like lower
No single home method handles every contaminant. That’s the best reason to read your report before you choose any system, ours included. Match the method to what’s actually in your water.
Take nitrate. Extension services list three established home methods: ion exchange, reverse osmosis and distillation. Boiling is not one of them. Penn State notes that boiling actually concentrates nitrate as the water evaporates. We compare the last two methods in Distillation vs Reverse Osmosis.
The John Ellis LWM-5 is built around steam distillation. It boils water into steam, leaves behind what can’t evaporate, and condenses the steam back into water. It adds repeated heating and cooling cycles and ultraviolet treatment. If you’ve read your report and want to talk about making your own water at home, call us at 845-754-8696, Monday through Friday, 10am–4pm ET. You can also ask for a free bottle of the water to taste.
Sources
- U.S. EPA, Find Your Local CCR, and EPA’s CCR guidance for column definitions (MCLG, MCL, TT, MRDL/MRDLG, “Your Water,” Range, Violation).
- U.S. EPA, Consumer Confidence Report Rule Revisions (finalized May 2024).
- American Water Works Association, EPA issues revised requirements for Consumer Confidence Reports.
- U.S. EPA, Proposed PFAS Rescission Rule and Proposed PFOA and PFOS Compliance Extension Rule (May 2026).
- Penn State Extension, Nitrates in Drinking Water: boiling, home treatment methods, private wells.
- Environmental Working Group, April 2026 nitrate analysis: the 1962 origin of the limit and EWG’s 0.14 mg/L benchmark.